Customization: | Available |
---|---|
Color: | White |
Usage: | Fuel |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Correct tank volume chart is key point for analysis of oil inventory, which is important in management for retail petroleum industry.
Due to the long term operation, the tank is possibly inclined or anamorphic. Then the tank volume will be not accurate. You need tank calibration system to recalibrate your tank to produce a new correct volume chart.
Work Principle
The volume measurement instrument (high flow dispenser) will measure the volume of oil product discharged from or into he tank. The probe will indicate the product level in the tank. Each product level correspond with a certain volume. Both data of volume and product level are collected by computer in real time, with intelligent data processing model, automatically create a tank volume chart.
Features
∗ High accuracy, the error is less than ±0.5%
∗ Advanced software creating the volume chart for tanks automatically, without need of manual operation
∗ Magnetostrictive probe with very high accuracy is specially designed for tank calibration
∗ High measuring speed (with High flow measurement dispenser), take less than 2 hours to measure an oil tank with 30 cubic meters
∗ The system automatically set height limit, preventing overflow in the process of calibration
∗ Two patterns working: Intermittent downtime working and continuous working
∗ The system is designed with protect data from losing function in case of outage
∗ For underground or above ground tanks
The Total System include
volume measurement instrument Magnetostrictive probe Laptop PC
Printer RS232-485 adaptor 2" delivery hose
High flow dispenser (volume measurement instrument)
Specification of high flow dispenser
Items | Content |
Accuracy for the unit | ±0.25% |
Digit of volume | Example:xxxxx.x |
Unit noise rate | <70dB; |
Repeatability | <±2‰ |
ExMark | Ex AT3 |
Flow Rate | 180~350L/min |
Power Supply | AC380V50Hz |
Environment Temperature | -25ºC~+55ºCor-40ºC~+55ºC |
Relative Humidity | 20%~95%RH |
Work Pressure | ≤0.48Mpa |
Application | Diesel,Gasoline,Kerosene |
Specifications of Probe
Item | PLS-5XProbe |
Function | Measuring product level,waterlevel,temperature |
Titles of Medium | Gasoline,diesel,kerosene,whiteoil,ethylalcohol,water |
Measured Variable | productlevel,waterlevel,5sensors' temperature andaverage temperature |
Field Display | PD-300(touched panel console),PM-1000(touched panel console) |
Product Level Accuracy | ±0.5mm |
Water Level Accuracy | ±0.5mm |
Temperature Accuracy | ±0.2ºC |
Resolution | 0.001mm |
Repeatability | ±0.1mm |
Explosive-proofgrade | ExiaIIBT4 |
Temperature | -40ºC~70ºC |
Lowest Product Inactive Zone | 100mm |
Lowest Water Inactive Zone | 15mm |
Probe Length | 0.6~4.0m(Customized length) |
Method of Communication | RS-485 |
Power Supply | +24~26VDC |
Probe Canister | IP68 |
Max Communication Distance | 1200m |
Probe Material | 1Cr18Ni9Ti |
Cable | 4-core shielded cable |